MQTT Template

Document Context

  • Purpose: Explains MQTT payload template system for customizing published message format with embedded device and meter variables
  • When to use: Configuring MQTT message payloads, integrating with specific IoT platforms, customizing data formats for downstream systems
  • Prerequisites: Basic JSON syntax, understanding of MQTT message publishing, familiarity with energy meter data fields (OBIS codes)
  • Related to: MQTT client configuration, local variables endpoint, energy measurements, system information fields
  • Validates against: Template variable resolution with real meter data and system information

Key Facts

  • Template syntax: ${variable_name} for embedding predefined variables
  • Message format: Text-based (typically JSON) with variable substitution
  • Variable types: Measurement variables (numeric) and system variables (text/numeric)
  • Variable resolution: Unresolved variables remain as literal ${name} strings
  • Data validation: Some variables may be null/empty if not provided by meter
  • Output format: Valid JSON after variable substitution
  • Predefined variables: Cannot define custom variables, only use system-provided ones
  • Error handling: Template errors result in literal variable strings in output

Template Description

The message published by the client is defined using a template. The message format can be anything but always text.

You can embed variables in the template, which can be both measurement and system variables. A variable in a template is embedded in a section starting with a dollar sign, followed by an opening curly brace, the variable name, and a closing curly brace: ${variable_name}

The available variables are predefined - you cannot define your own at this time.

Variable Resolution

If a variable appears in the template that is not resolved, then the variable will not be replaced and the entire ${some_undefined_variable} string will be in the output message. Be careful when integrating with your system - some variables may be null (numeric) or empty string (text) if not sent by the meter.

Example Template

{
  "P_In": ${1_7_0},
  "P_Out": ${2_7_0},
  "E_In": ${1_8_0},
  "E_Out": ${2_8_0},
  "Meter": {
    "DateTime": "${meter.date_time}"
  },
  "Sys": {
    "Id": "${sys.id}"
  }
}

Note

This is not valid JSON until all variables are resolved. Note that some variables are always numeric (written as text) and some are text - in JSON payload you need to enclose text variables in quotes.

Example Generated Message

After variable substitution, the template generates a valid JSON message:

{
  "P_In": 0.014,
  "P_Out": 0,
  "E_In": 200.934,
  "E_Out": 8.965,
  "Meter": {
    "DateTime": "2025-11-17T15:52:50Z"
  },
  "Sys": {
    "Id": "ECC9FF5C7F14"
  }
}

Available Variables

The first column Name usually refers to short OBIS form part C.D.E. Keep in mind that the meter does not send all fields. The value returned for a network interface depends on which one is connected.

Energy Variables

Variable Type Unit Description
1_8_0 double kWh Positive active energy (A+) total
energy.in double kWh Positive active energy (A+) total
1_8_1 double kWh Positive active energy (A+) in tariff T1
1_8_2 double kWh Positive active energy (A+) in tariff T2
2_8_0 double kWh Negative active energy (A-) total
energy.out double kWh Negative active energy (A-) total
2_8_1 double kWh Negative active energy (A-) in tariff T1
2_8_2 double kWh Negative active energy (A-) in tariff T2

Max Demand Variables

Variable Type Unit Description
1_6_0 double kW Positive active maximum demand (A+) total
1_6_1 double kW Positive active maximum demand (A+) in tariff T1
1_6_2 double kW Positive active maximum demand (A+) in tariff T2
2_6_0 double kW Negative active maximum demand (A-) total
2_6_1 double kW Negative active maximum demand (A-) in tariff T1
2_6_2 double kW Negative active maximum demand (A-) in tariff T2

Power Variables

Variable Type Unit Description
1_7_0 double kW Positive active instantaneous power (A+)
power.in double kW Positive active instantaneous power (A+)
21_7_0 double kW Positive active instantaneous power (A+) in phase L1
41_7_0 double kW Positive active instantaneous power (A+) in phase L2
61_7_0 double kW Positive active instantaneous power (A+) in phase L3
2_7_0 double kW Negative active instantaneous power (A-)
power.out double kW Negative active instantaneous power (A-)
22_7_0 double kW Negative active instantaneous power (A-) in phase L1
42_7_0 double kW Negative active instantaneous power (A-) in phase L2
62_7_0 double kW Negative active instantaneous power (A-) in phase L3
9_7_0 double kVA Apparent instantaneous power (S+)

Reactive Power & Energy

Variable Type Unit Description
3_7_0 double kvar Positive reactive instantaneous power (Q+)
23_7_0 double kvar Positive reactive instantaneous power (Q+) in phase L1
43_7_0 double kvar Positive reactive instantaneous power (Q+) in phase L2
63_7_0 double kvar Positive reactive instantaneous power (Q+) in phase L3
4_7_0 double kvar Negative reactive instantaneous power (Q-)
24_7_0 double kvar Negative reactive instantaneous power (Q-) in phase L1
44_7_0 double kvar Negative reactive instantaneous power (Q-) in phase L2
64_7_0 double kvar Negative reactive instantaneous power (Q-) in phase L3
3_8_0 double kvarh Positive reactive energy (Q+) total
3_8_1 double kvarh Positive reactive energy (Q+) in tariff T1
3_8_2 double kvarh Positive reactive energy (Q+) in tariff T2
4_8_0 double kvarh Negative reactive energy (Q-) total
4_8_1 double kvarh Negative reactive energy (Q-) in tariff T1
4_8_2 double kvarh Negative reactive energy (Q-) in tariff T2
5_8_0 double kvarh Imported inductive reactive energy Q1 total
5_8_1 double kvarh Imported inductive reactive energy Q1 in tariff T1
5_8_2 double kvarh Imported inductive reactive energy Q1 in tariff T2
6_8_0 double kvarh Imported capacitive reactive energy Q2 total
6_8_1 double kvarh Imported capacitive reactive energy Q2 in tariff T1
6_8_2 double kvarh Imported capacitive reactive energy Q2 in tariff T2
7_8_0 double kvarh Exported inductive reactive energy Q3 total
7_8_1 double kvarh Exported inductive reactive energy Q3 in tariff T1
7_8_2 double kvarh Exported inductive reactive energy Q3 in tariff T2
8_8_0 double kvarh Exported capacitive reactive energy Q4 total
8_8_1 double kvarh Exported capacitive reactive energy Q4 in tariff T1
8_8_2 double kvarh Exported capacitive reactive energy Q4 in tariff T2

Voltage & Current

Variable Type Unit Description
32_7_0 double V Instantaneous voltage (U) in phase L1
52_7_0 double V Instantaneous voltage (U) in phase L2
72_7_0 double V Instantaneous voltage (U) in phase L3
31_7_0 double A Instantaneous current (I) in phase L1
51_7_0 double A Instantaneous current (I) in phase L2
71_7_0 double A Instantaneous current (I) in phase L3
s31_7_0 double A Signed instantaneous current (I) in phase L1
s51_7_0 double A Signed instantaneous current (I) in phase L2
s71_7_0 double A Signed instantaneous current (I) in phase L3

System & Meter Variables

Variable Type Unit Description
timestamp uint UTC UNIX timestamp
tariff uint Current tariff (1,2); may be 0/absent if unknown
conv_factor double Conversion coefficient for power/energy/current values
13_7_0 double Instantaneous power factor
meter.date_time string ISO8601 Report date time (local)
meter.date_time_local string ISO8601 Report date time (local)
meter.date_time_utc string ISO8601 Report date time (UTC)
meter.id string Meter ID
meter.type string Meter type
meter.vendor string Meter vendor
meter.model string Model of meter
meter.interface string Physical interface (P1, TTL, MBUS, MEP)
meter.protocol string Protocol (DSMR, DLMS, KMP, MEP)
meter.protocol_ver string Meter protocol version
meter.status string Connection status (NOT CONNECTED, NO DATA, OK, etc.)
sys.name string Name of device (settable via WebUI)
sys.id string whatwatt Go system identifier
sys.firmware string Firmware version
sys.date_time string ISO8601 System local time
sys.date_time_local string ISO8601 System local time (explicit local variant)
sys.date_time_utc string ISO8601 System time in UTC

Network Interface Variables

Variable Type Unit Description
wifi.mode string Wi-Fi operation mode (off, sta, ap, apsta, nan)
wifi.sta.status string Connection status (disabled, disconnected, error, ok)
wifi.sta.ssid string Name of connected Wi-Fi network
wifi.sta.bssid string MAC MAC address of AP
wifi.sta.rssi int dBm Wi-Fi received signal strength indication
wifi.sta.channel uint Wi‑Fi channel (1–13)
wifi.sta.mac string MAC MAC address of Wi‑Fi interface
wifi.sta.ip string IPv4 IPv4 address assigned to Wi-Fi interface
wifi.sta.mask string IPv4 IPv4 netmask assigned to Wi‑Fi interface
wifi.sta.gw string IPv4 IPv4 gateway address assigned to Wi‑Fi interface
wifi.sta.dns string IPv4 IPv4 DNS server assigned to Wi‑Fi interface
eth.state string Status of Ethernet (up, down)
eth.mac string MAC MAC address of Ethernet interface
eth.ip string IPv4 IPv4 address assigned to Ethernet interface
eth.mask string IPv4 IPv4 netmask assigned to Ethernet interface
eth.gw string IPv4 IPv4 gateway address assigned to Ethernet interface
eth.dns string IPv4 IPv4 DNS server assigned to Ethernet interface

Hardware Variables

Variable Type Unit Description
plug.interface string Physical interface connected (NONE, P1, TTL, MBUS, MEP)
plug.voltage.usb double V USB voltage
plug.voltage.p1 double V P1 voltage
plug.voltage.mbus double V M-Bus voltage

Volume Array Variables

When multi-volume (multi-bus) data is available, indexed volume entries are exposed using zero-based sequential indices assigned at report generation time. Each entry corresponds to a physical bus channel and carries cumulative information.

Variable name pattern: vol[n].field where n is the 0-based array index.

Variable Type Description
vol[n].bus int Bus number (1-based as reported by meter)
vol[n].meter_id string Meter identifier for this bus (if available)
vol[n].date_time string ISO8601 timestamp (UTC) for the volume snapshot
vol[n].cumulative double Cumulative counter value (unit depends on meter context)

Notes:

  • Volume entries appear only when the meter reports them; absent otherwise.
  • Index ordering matches bus enumeration order during report processing.
  • Cumulative unit is typically an energy counter (e.g., kWh) — consult meter specification.

Additional Notes

  • Date/time variants (*_local, *_utc) provide both localized and UTC forms to simplify template usage across systems with different time zone handling.
  • Treat missing or zero tariff as unknown/not yet determined.